ALL INTELLIGENCE
Hacker News AIT2·Open Source

Logitech Harmony IR Database Archived with 276,000 Devices

Original title: Logitech Harmony IR code online database archive
58AI Score

A developer has scraped and open-sourced Logitech's discontinued Harmony universal remote infrared database as plain JSON, covering roughly 276,000 devices from 7,900 manufacturers, 13.3 million commands, and all 684 proprietary IR protocol definitions. Each command retains its original keycode and a ready-to-send Pronto Hex string, usable offline without any Logitech account or service.

Full Report

Contents7 sections

Logitech Harmony IR archive

AI Disclaimer

I heavily used AI in creating this archive.

TL;DR - Just give me the data

Don't care about my attempt, with Claudes help, to pull out the relevant data? Don't blame you :)

Check the files attached to the 20261110 release.

They are the unfiltered raw data I captured to do with as you see fit.

Overview

The infrared control database from Logitech's Harmony universal remotes: about 276,000 devices from 7,900 manufacturers, 13.3 million commands, and all 684 of Logitech's own IR protocol definitions. manifest.json has the current counts.

Harmony is mostly discontinued, and this data lived only on Logitech's servers. It is all plain JSON, and using it needs no Logitech service, no account, and no tooling beyond what is in this repository.

Every command has its original Harmony keycode and, where it is infrared, a ready-to-send Pronto Hex string. Every protocol has Logitech's original definition, so you can render any command yourself instead of trusting ours. Devices also record how to drive them: timing, whether power is discrete or a toggle, their inputs, and how channel numbers are dialled.

One convention applies throughout: an optional field that has no value is absent. It is never null, {} or a placeholder. Test whether the key exists, not whether its value is falsy.

Looking something up

The page. index.html is a single file with no build step and no dependencies. Double-click it and use Open archive folder… to pick the folder holding manifest.json. It reads the files in place, and nothing is uploaded. This needs the File System Access API, which Chromium browsers have and Firefox and Safari do not. In any browser, you can instead serve the folder and open it over http://:

BASH
python3 -m http.server 8000     # or any static file server, run from the archive root

By hand.

BASH
jq -r '.[] | select(.n=="Sony") | .s' index.json           # -> Sony
jq -r '.[] | select(.m=="CDP222ES") | .f' devices/Sony/index.json
jq . devices/Sony/CDP222ES.json
jq -r '.commands[] | "\(.name)\t\(.pronto)"' \
   "$(jq -r .codeset devices/Sony/CDP222ES.json)"

Rehydrated. rehydrate.py writes self-contained device files with the commands inlined:

BASH
python3 rehydrate.py --manufacturer Sony --out /tmp/sony
python3 rehydrate.py --model-file my-devices.txt --out /tmp/mine
python3 rehydrate.py --all --out /tmp/everything      # ~5.8 GB

rehydrate.ps1 does the same in PowerShell. Windows PowerShell 5.1 is slow at parsing JSON, so use Python or PowerShell 7 for anything bigger than one manufacturer.

Schema

manifest.json

fieldmeaning
schemaVersionbumped on any breaking field change. Pin it if you parse this
generatedbuild date, YYYY-MM-DD
sourcewhere the data came from
countsmanufacturers, devices, devicesWithCodes, devicesWithTiming, devicesWithControl, commands, commandsWithPronto, codesets, protocols
layoutthe path patterns, so a consumer never hard-codes them
notesrendering caveats that apply to the whole archive

devices/<Manufacturer>/<Model>.json

A real one, devices/Magnavox/RJ5540.json, with its timing block removed:

JSON
{"manufacturer": "Magnavox",
 "model": "RJ5540",
 "globalDeviceId": 636,
 "deviceType": 1,
 "codeset": "codesets/3b/3b3e7eddcbfe948a.json",
 "power": {"type": "toggle", "toggle": ["PowerToggle"]},
 "inputs": {"type": 1,
            "list": [{"name": "VCR/AUX", "commands": ["InputNext", {"delayMs": 500}, "InputAux"]},
                     {"name": "TV", "commands": ["InputNext", {"delayMs": 500}, "InputTuner"]}]}}

This device has no discrete power command, and to reach either input you press InputNext, wait half a second, then press the one you want. Its command list alone would not tell you that.

fieldmeaning
manufacturer, modelverbatim, spelled as Logitech spells them. Read these rather than the filename (see Filenames)
globalDeviceIdLogitech's permanent catalogue id, and this file's stable identity
deviceTypeLogitech's device-type code (1 TV, 2 VCR, 3 CD, 4 DVD, …)
codesetpath to the device's command set, relative to the archive root, or null for a device with no commands
timingdelays and repeat counts. See Timing
power, inputs, channelTuning, stateshow to control it. See Control

(注:更多技术实现细节与完整 API 文档请查阅原项目 README)